Standing for high rate, the HR series is designed to provide power backup for smaller output applications like those found in personal or business power backup applications. The HR family is VRLA-AGM construction, which means the battery is maintenance free, no need to add water and able to be installed in multiple physical orientations without affecting service life.
Features
Capacity range is from 18W/cell to 120W/cell (15min-rate @1.67Vpc).
Wafer-thin plate technology combined with special proprietary formula utilizing 99.99% pure lead ingot in production for lead oxide, lead plate grids, and other lead components.
Design life of up to 5 years in standby service.
Optional flame-retardant ABS case construction.
UL recognized under UL 1989 (file number MH14533).
Comply with IATA/ICAO Special Provision A67 for air transport, are classified per MG Amendment 27 as a non-hazardous material for water transport, and recognized by DOT as “Dry charge” 49 CFR 171-189 for surface transport.
HRL series, standing for high-rate long life, takes our HR and UPS series and expands upon its exceptional performance across various high-power backup power requirements.
Features
Capacity range is from 10W/cell to 540W/cell (15min-rate @ 1.67Vpc).
Wafer-thin plate technology combined with special proprietary formula utilizing 99.99% pure lead ingot in production for lead oxide, lead plate grids, and other lead components.
Design life of up to 10 years in standby service.
Optional flame-retardant ABS case construction.
UL1973 Certified (file number MH66728) + UL recognized under UL1989 (file number MH14533).
Comply with IATA/ICAO Special Provision A67 for air transport, are classified per MG Amendment 27 as a non-hazardous material for water transport, and recognized by DOT as “Dry charge” 49 CFR 171-189 for surface transport.
Standing for uninterruptible power supply, the UPS series is the first in a lineup of premium quality offerings from CSB for the UPS power application market. UPS series are specifically designed for high power discharge applications, like those found in data centers of today. Our UPS series uses the latest wafer-thin plate technology combined with special proprietary formula, all to provide optimum high-rate performance.
Features
Capacity range is from 40W/battery to 96W/battery per cell (15-min rate @ 1.67 VPC).
Utilizing 99.99% pure lead ingot in production for lead oxide, lead plate grids, and other lead components.
Design life of up to 5 years in standby service.
Optional flame-retardant ABS case construction.
UL recognized under UL 1989 (file number MH14533).
Comply with IATA/ICAO Special Provision A67 for air transport, are classified per MG Amendment 27 as a non-hazardous material for water transport and recognized by DOT as “Dry charge” 49 CFR 171-189 for surface transport.
XHRL series is our premium offering in high-rate power backup applications meant for EMEA markets, taking HR, UPS, and HRL designs even further to provide extended service life and even higher power density in both front and top terminal designs.
Features
Capacity range is from 360W/cell to 650W/cell (15min-rate @ 1.67Vpc).
Wafer-thin plate technology combined with special proprietary formula utilizing 99.99% pure lead ingot in production for lead oxide, lead plate grids, and other lead components.
Design life of up to 10 years in standby service.
Optional flame-retardant ABS case construction.
UL1973 Certified (file number MH66728) + UL recognized under UL1989 (file number MH14533).
Comply with IATA/ICAO Special Provision A67 for air transport, are classified per MG Amendment 27 as a non-hazardous material for water transport, and recognized by DOT as “Dry charge” 49 CFR 171-189 for surface transport.
More than just a high-performance battery, Calor XHT-FT stands alone as the problem-solver to help data center operators meet sustainability goals with reduced cooling costs, extend battery replacement life, and perform at extreme power discharge requirements. XHT-FT can deliver maximum power within 30 seconds to ensure connectivity stays intact in extreme elevated temperature environments. Our innovative In-Case Formation (ICF) process combined with proprietary catalyst introduction and PC-ABS plastics, XHT enhances charging efficiency and provides consistent battery capacity over the available service life at elevated temperatures. XHT also has an optional front and top terminal connection design for ease of installation and maintenance. With an industry-leading warranty to provide peace of mind, XHT from CSB is the trusted battery provider for all mission critical power needs in all environments.
Features
Valve Regulated Lead Acid (VRLA) Battery, Maintenance-Free
Absorbent Glass Mat (AGM) with Exclusive Grid for 99% Gas Recombination.
Pure Lead Construction and Catalist 2X Proprietary Additive Technology
Constructed with High-Impact Resistant ABS Plastic (UL 94-V0)
Designed for High-Rate and High-Temperature Standby Applications
Optimized for Harsh Environments with Extended Service Life
Built in Accordance with IEC 60896-21/22:2004, UL1989(MH14533) and UL 1973 (MH66728)
XPL series is our premium offering in high-rate power backup applications meant for N. America, S. America, and Asia-Pacific markets, taking HR, UPS, and HRL designs even further to provide extended service life and even higher power density in top terminal designs.
Features
Capacity range is from 200W/cell to 650W/cell (15-min rate @ 1.67Vpc).
Wafer-thin plate technology combined with special proprietary formula utilizing 99.99% pure lead ingot in production for lead oxide, lead plate grids, and other lead components.
Design life of up to 10 years in standby service.
Optional flame-retardant ABS case construction.
UL1973 Certified (file number MH66728) + UL recognized under UL1989 (file number MH14533).
Comply with IATA/ICAO Special Provision A67 for air transport, are classified per MG Amendment 27 as a non-hazardous material for water transport and recognized by DOT as “Dry charge” 49 CFR 171-189 for surface transport.
XPL-FT series is our premium offering in high-rate power backup with a front terminal design for even higher power density in shorter duration, up to 30 seconds. XPL-FT uses a unique separator design combined with pure lead construction. XPL-FT batteries are meant for data center applications in N. America, S. America, and Asia-Pacific markets, taking HR, UPS, and HRL designs even further to provide extended service life and even higher power density in front terminal designs.
Features
Capacity range is from 1100W/cell to 1400W/cell of 12V battery (5-min rate @ 1.67Vpc).
Wafer-thin plate technology combined with special proprietary formula utilizing 99.99% pure lead ingot in production for lead oxide, lead plate grids, and other lead components.
Design life of up to 10 years in standby service.
Optional flame-retardant ABS case construction.
UL1973 Certified (file number MH66728) + UL recognized under UL1989 (file number MH14533).
Comply with IATA/ICAO Special Provision A67 for air transport, are classified per MG Amendment 27 as a non-hazardous material for water transport, and recognized by DOT as “Dry charge” 49 CFR 171-189 for surface transport.